Impact of Microclimate and Indoor Plants on Air Ion Concentration

Authors

  • Natalia Sinicina Rezeknes Augstskola (LV)
  • Andris Skromulis Rezeknes Augstskola (LV)
  • Andris Martinovs Rezeknes Augstskola (LV)

DOI:

https://doi.org/10.17770/etr2013vol1.827

Keywords:

Air ions, Indoor plants, Microclimate

Abstract

Saturation of air ions is essentially important for all living beings, especially for human health. Existing sanitary norms provide that concentration of small ions has to be in range of 400-50000 ions cm-3 and unipolarity coefficient 0.4 ≤ K ≤ 1.0. Many species of indoor plants emit organic volatile compounds and air ions, therefore they could be used for improving the quality of indoor air. The results show that ionization level of indoor air is significantly insufficient and selected species of indoor plants are not able to improve it. They serve rather as supplementary surfaces for ion absorption. Possible interaction between microclimate, ion concentration and indoor plants in different times of the day is analyzed.

Downloads

Download data is not yet available.

References

Dolezalek H., Reiter R., Kröling P. (1985) Basic comments on the physics, occurrence in the atmosphere, and possible biological effects of air ions. Int. J. Biometeorol., No. 29, pp. 207-242

Tammet H. (1998) Air ions. In: CRC Handbook of Chemistry and Physics, 79th edition, No. 14, Boca Raton, Ann Arbor, London, Tokyo: CRC Press, 1998, pp. 32-34.

Tammet H. (2011) Symmetric Inclined Grid Mobility Analyzer for the Measurement of Charged Clusters and Fine Nanoparticles in Atmospheric Air. Aerosol Science and Technology, No. 45, pp. 468–479.

Hõrrak U., Salm J., Tammet H. (2000) Statistical characterization of air ion mobility spectra at Tahkuse Observatory: classification of air ions. J. Geophys. Res. Atmos., No. 105, pp. 9291–9302.

Rim Y. (1977) Psychological Test Performance of Different Personality Types on Sharav Days in Artifical air Ionisation. Int. J. Biometeor., Vol. 21, number 4, pp 337 – 340.

Charry J. M. (1984) Biological effects of small air ions: A review of findings and methods. Environmental Research, Vol. 34, Issue 2, pp. 351-389.

Fornof K.T., Gilbert G.O. (1988) Stress and physiological, behavioral and performance patterns of children under varied air ion levels, Int J. Biometeorol, No. 32, pp. 260-270.

Danze, J.M. L'ionisation de l’oxygene. [Elektronic resource]/ (16.08.2007.) http://www.delvaux-danze.be/ioniation.htm

Livanova L. M., Levshina I. P., Nozdracheva L. V., Elbakidze M. G., Airapetyants M. G. (1999) The Protective Effects of Negative Air Ions in Acute Stress in Rats with Different Typological Behavioral Characteristics, Neuroscience and Behavioral Physiology, Vol. 29, No. 4, pp. 393-395.

Jaskowski J., Mysliwski A. (1986) Effect of air ions on healing of wounds of rat skin. Experimental Pathology, Vol. 29, Issue 2, pp. 113-117.

Герасимова Л. И., Данилов Ю. А., Евстигнеев А. Р., Мачабели М., С., Тихонов В. П. (1996) Аэроионотерапия. Калуга: Лазерная Академия Наук Российской Федерации, 1996, c. 5-13.

Krueger A. P., Smith R. F., Go I. G. (1957) The Action of Air Ions on Bacteria: Protective and Lethal Effects on Suspensions of Staphylococci in Droplets. JGP, Vol. 41, No. 2, pp. 359-381.

Kellogg E. W. (1984) Air Ions: their Possible Biological Significance and Effects. Electromagnetic Biology and Medicine, Vol. 3, No.1-2, pp. 119-136.

Рейнет Я. Ю. (1983) О Нормах аэроионов в помещениях. Ученые записи Тартуского Государственного Университета, No. 648, c. 46-51.

Hawkins L. H., Barker T. (1978) Air Ions on Human Performance. Ergonomics, Volume 21, Issue 4, pp. 273-278.

Hawkins L. H. (1981) The influence of air ions, temperature and humidity on subjective wellbeing and comfort. Journal of Environmental Psychology, Vol. 1, Issue 4, pp. 279-292.

Прийман Р. Э. (1984) О понятии "Свежесть воздуха". Ученые записи Тартуского Государственного Университета, No. 669, c. 115-121.

Shiue A., Hu S. C. (2011) Contaminant particles removal by negative air ionic cleaner in industrial minienvironment for IC manufacturing processes. Building and Environment, Vol. 46, Issue 8, pp. 1537-1544.

Kim Y. S., Yoon K. Y., Park J. H., Hwang J. (2011) Application of air ions for bacterial de-colonization in air filters contaminated by aerosolized bacteria. Science of the Total Environment, Vol. 409, Issue 4, pp. 748-755.

Wang J., Li S. H. (2009) Changes in negative air ions concentration under different light intensities and development of a model to relate light intensity to directional change. Journal of Environmental Management, Vol. 90, Issue 8, pp. 2746-2754.

Tammet H. and Kimmel V. (1998) Electrostatic deposition of radon daughter clusters on the trees. J. Aerosol Sci. 29, pp. 473–S474

Hoffmann T., Bandur R., Marggraf U., Linscheid M. (1998) Molecular composition of organic aerosols formed in the α- pinene/O3 reaction: Implications for new particle formation processes. Journal of Geophysical Research: Atmospheres (1984–2012) Vol. 103, Issue D19, pp. 25569–25578.

Kulmala M., Hämeri K., Aalto P.P., Mäkelä J. M., Pirjola L., Nilsson E., Buzorius G., Rannik Ü., Dal Maso M., Seidl W., Hoffman T., Janson R., Hannson H.-C., Viisanen Y., Laaksonen A., O’Dowd C. D. (2000) Overview of the international project on biogenic aerosol formation in the boreal forest (BIOFOR). Tellus B, Vol. 53, Issue 4, pp 324– 343.

Скипетров В. П., Еникеев О. Л., Зорькина А. В., Иничина В. И., Мартынова В. В. (1995) Аэроионы и жизнь. Саранск: Изд-во Мордов. университета, 1995, 96 с.

Г.Л.Спичкин, К.В.Воробьев, М.П.ФеО.В. Войцеховскаядоров, О.Ю.Кудрявцев. Влияние антропогенных аэроионных воздействий на фотосинтез Tradescantia fluminensis Vell. Санкт-Петербургский государственный политехнический Университет Ботанический Институт им. В. Л. Комарова РАН [Elektronic resource]/ООО «НПО «Фитотехнология» - http://phyteco.ru/o_nas/publikatsii (01.03.2013)

М.П. Федоров, Г.Л. Спичкин, К.В.Воробьев, О.Ю.Кудрявцев. «Комнатные растения против органических загрязнителей». Экология и жизнь, № 11(84), 2008, 80. - 85. lpp [Elektronic resource]/http://www.ecolife.ru/arhiv/flash/84%2811- 2008%29.html (15.03.2013)

Цыбуля Н.В., Фершалова Т.Д. Фитонцидные растения в интерьере (оздоровление воздушной среды с помощью растений). – Новосибирск: Новосибирское книжное изд- во, 2000 – 112. lpp.

Федоров М.П., Воробьев К.В., Замараева В.С., Спичкин Г.Л. «Аэроионы для здоровья». Экология и жизнь, № 8(81), 2008, 78. – 82. lpp.[ Elektronic resource]/http://www.ecolife.ru/arhiv/flash/81%288- 2008%29.html- (15.03.2013)

Воздушные «витамины»- отрицательно заряженные ионы [Elektronic resource]/ http://www.lucklife.net/view_lucklife/378.htm- Resurss apskatīts (27.03.2013)

Duddington C.L. Evolution in plant design. London. 1969. 304. lpp.[Elektronic resource]/ http://catalogue.nla.gov.au/Record/1852814.pdf (10.03.2013)

Николас Д. Биоэнергетика. Введение в хемиосмотическую теорию. М., Мир, 1985.g. 146.lpp.[Elektronic resource]/http://cyberpirate.me/bittorrent/viewtopic.php?t=3770865 (10.03.2013)

Сорокина А. «Кладовая здоровья на грядке и в лесу»[Elektronic resource] http://maga3in.ru/Library.asp?DocId=113&SecId=6&ord=5(15.03.2013)

Фитостена: как создать тропический сад у себя дома -[Elektronic resource] http://www.moydesign.ru/book/export/html/1190(15.03.2013)

Ю. Синадский «Целительные силы природы» -[ Elektronicresource] http://www.florets.ru/tainy-rastenii/tselebnyivozduh.html (15.03.2013)

Санитарно-эпидемиологические правила и нормативы"Гигиенические требования к аэроионному составу воздуха производственных и общественных помещений СанПин 2.2.4 1294-03")

Downloads

Published

2015-08-06

How to Cite

[1]
N. Sinicina, A. Skromulis, and A. Martinovs, “Impact of Microclimate and Indoor Plants on Air Ion Concentration”, ETR, vol. 1, pp. 66–72, Aug. 2015, doi: 10.17770/etr2013vol1.827.